Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Ophthalmologie ; 121(5): 397-406, 2024 May.
Artigo em Alemão | MEDLINE | ID: mdl-38502347

RESUMO

BACKGROUND: The major problem associated with the benign but destructive growing pterygium is the high recurrence rate. A new surgical technique to lower recurrence rates is minor ipsilateral simple limbal epithelial transplantation (mini-SLET), where the regeneration potential of limbal stem cells is used in combination with amniotic membrane transplantation (AMT) for surgical reconstruction. The aim of this study is to assess the surgical outcome of the mini-SLET technique with tenonectomy, mitomycin C, and AMT as used in the authors' hospital. MATERIALS AND METHODS: A total of 16 eyes from 15 patients undergoing mini-SLET after surgical pterygium removal with tenonectomy, mitomycin C, and AMT were analyzed retrospectively. Two different groups of pterygia were enrolled: group 1 included recurrent pterygia (n = 10) and group 2 comprised primary large pterygia such as double-head pterygia (n = 6). In addition to assessment of best corrected visual acuity and compete ophthalmological examination, preoperative slip-lamp examination with photo documentation served to calculate the corneal size of the pterygium head using VISUPAC software (Zeiss, Oberkochen, Germany). Postoperatively, best corrected visual acuity and slit-lamp examination were routinely evaluated. The surgical outcome was defined by the postoperatively achieved best corrected visual acuity, restoration of the ocular surface, recurrence rate, and rate of postoperative complications. RESULTS: Median follow-up in all patients was 27 months; in groups 1 and 2 it was 30.7 and 25.3 months, respectively. No recurrence developed in 15 eyes (93.75%). Only one group 1 patient (6.25%) suffered a recurrent lesion after 10 months. Postoperatively, logMAR visual acuity did not change significantly. During follow-up, complications were limited to one case of early wound dehiscence. CONCLUSION: Mini-SLET in combination with tenonectomy, mitomycin C, and AMT enables good surgical reconstruction of the ocular surface, and almost complete healing in the sense of restitutio ad integrum is possible. The results of the present study have shown the technique's effectiveness for recurrence prevention.


Assuntos
Âmnio , Pterígio , Humanos , Pterígio/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Âmnio/transplante , Estudos Retrospectivos , Limbo da Córnea/cirurgia , Acuidade Visual/fisiologia , Resultado do Tratamento , Adulto , Mitomicina/uso terapêutico , Mitomicina/administração & dosagem , Transplante de Células-Tronco/métodos , Terapia Combinada , Recidiva
3.
Ophthalmologie ; 121(2): 135-140, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-38253895

RESUMO

BACKGROUND: Optic disc swelling poses a diagnostic challenge due to its multiple underlying pathological causes. This study aimed to investigate the use of fluorescein angiography (FLA) in combination with optical coherence tomography (OCT) as a diagnostic tool for differentiating between papilledema and papillitis in cases of optic disc swelling. MATERIAL AND METHODS: A total of 12 patients were included in the study in whom both FLA and OCT of the optic disc were performed to evaluate the optic disc swelling in cases of papilledema (7 patients, 14 eyes) and papillitis (5 patients, 7 eyes). The fluorescence behavior of the optic disc during late phase FLA was examined in relation to papillary thickness measured by OCT. RESULTS AND DISCUSSION: In the papilledema group OCT revealed a mean papillary thickness of 873 µm. In 6 patients FLA detected a ring-shaped papillary hyperfluorescence with papillary thicknesses ranging from 611 µm to 972 µm. Another patient with chronic and marked papilledema exhibited bilateral panpapillary leakage in FLA and papillary thicknesses of 1287 µm (right eye) and 1526 µm (left eye). In the papillitis group FLA showed panpapillary leakage in all cases. The mean papillary thickness was 865 µm (range 632-1195 µm). CONCLUSION: In acute optic disc swelling and a papillary prominence less than 1000 µm in OCT, a difference in FLA was noticeable between papilledema and papillitis. While acute and mild papilledema exhibited a ring-shaped hyperfluorescence, papillitis showed a panpapillary leakage in late phase FLA in the examined cases. This difference could not be seen in the case of papilledema with chronic and severe swelling.


Assuntos
Disco Óptico , Papiledema , Humanos , Papiledema/diagnóstico , Angiofluoresceinografia/efeitos adversos , Disco Óptico/diagnóstico por imagem , Tomografia de Coerência Óptica/efeitos adversos , Fibras Nervosas/patologia
4.
Diagnostics (Basel) ; 13(21)2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37958269

RESUMO

Trabeculectomy has traditionally been upheld as the gold standard in glaucoma surgery, but recent advancements, including the PRESERFLO® MicroShunt, have introduced less invasive techniques to mitigate complications and reduce intraocular pressure (IOP). The examination of bleb morphology post-filtering surgery is critical for modulating wound healing and ensuring long-term success. While previous evaluations of PRESERFLO-generated blebs have relied on data from trabeculectomy blebs, the differing surgical techniques used in PRESERFLO and trabeculectomy surgeries suggest potential variations in bleb morphologies. This study conducted a comparative analysis of blebs resulting from PRESERFLO and trabeculectomy procedures. Retrospective descriptive assessments using the Jenaer Bleb Grading System were performed, along with quantitative evaluation using eight-dimensional parameters utilizing anterior segment OCT. We included 93 eyes (57 following PRESERFLO, 36 following trabeculectomy). In the descriptive assessment, PRESERFLO-generated blebs exhibited fewer conjunctival cysts (3.5% vs. 22.2%, p = 0.007) and cavernous changes (10.5% vs. 30.5%, p = 0.021) compared to trabeculectomy. Quantitatively, overall bleb dimensions were comparable (maximal bleb height, width, and length, p > 0.05 for all). However, PRESERFLO blebs displayed a shallower (0.52 ± 0.24 vs. 0.67 ± 0.3 mm, p = 0.017) yet longer (4.12 ± 1.54 vs. 3.23 ± 1.64 mm, p = 0.024) episcleral lake. A thicker bleb wall (1.52 ± 0.46 vs. 1.10 ± 0.37 mm, p < 0.001) along with more posteriorly positioned blebs (distance to limbus = 6.16 ± 1.36 vs. 4.87 ± 1.34 mm, p < 0.001) were observed following PRESERFLO. This study illuminates the nuanced morphological differences between PRESERFLO and trabeculectomy blebs. Understanding these distinctions is vital, empowering clinicians to make informed postoperative decisions and avoid misinterpretation of bleb morphology.

5.
Transl Vis Sci Technol ; 12(11): 4, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37917087

RESUMO

Purpose: Evaluating bleb morphology is crucial after glaucoma filtering surgery. Advances in anterior segment optical coherence tomography (AS-OCT) allow for objective assessment. While various parameters differentiate functional from failed blebs, limited information exists regarding variations within functional blebs. This study aimed to identify factors influencing morphology of functional blebs following implantation of Preserflo MicroShunt. Methods: Eyes with functional blebs after Preserflo were retrospectively included. Age, gender, lens status, preoperative intraocular pressure (pre-IOP) and number of glaucoma medications were documented along with biometric measurements as axial length (AL), white-to-white distance, and anterior chamber depth. Postoperative data included time elapsed since surgery (TaS) and postoperative IOP (post-IOP). Bleb dimensions were measured using AS-OCT including maximal bleb height (MBH), width, length (MBL), bleb wall thickness (BWT), and bleb distance to limbus (DtL) along with dimensions of episcleral lake (maximal height, width [MLW], and length). Linear regression models were applied to correlate these parameters with bleb dimensions. Results: Included were 50 eyes from 50 patients. Mean IOP decreased from 25.3 ± 10.0 to 11.9 ± 3.0 mm Hg after 278.5 ± 221.9 days after surgery. MBH correlated negatively with age (unstandardized coefficients [uSC] = -0.012) and TaS (uSC = -0.001, P = 0.008 for both). BWT correlated negatively with age (uSC = -0.013, P = 0.02), MBL with AL (uSC = -0.566, P = 0.01) and MLW with pre-IOP (uSC = -0.073, P = 0.02). DtL exhibited a positive correlation with post-IOP (uCS = 0.136, P = 0.02). Conclusions: Morphology of functional blebs might be influenced by multiple factors such as age, TaS, AL, and pre- and post-IOP. Translational Relevance: Age, time after surgery, axial length, and preoperative and postoperative IOP could affect the morphology of a functional bleb; hence, these factors should be taken into consideration when making treatment decisions.


Assuntos
Glaucoma , Tomografia de Coerência Óptica , Humanos , Estudos Retrospectivos , Glaucoma/diagnóstico , Glaucoma/cirurgia , Pressão Intraocular , Esclera/cirurgia
6.
Graefes Arch Clin Exp Ophthalmol ; 261(11): 3249-3255, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37410178

RESUMO

PURPOSE: The success of filtering surgery as in XEN-Gel-Stent (XEN) and Preserflo-Microshunt (PF) depends mainly on a functioning bleb. Primary bleb failure (PBF) is not uncommon and can be treated with needling or open bleb revision (OBR). The aim of the study is to compare surgical outcomes of OBR after XEN and PF. METHODS: Eyes which received OBR as management of PBF following implantation of XEN or PF were retrospectively included. Intraocular pressure (IOP), number of IOP lowering medications (NoM), and success rates (SR) were compared between groups. Complete and qualified success were defined as IOP ≤18mmHg and a reduction of >20%, without and with medications, respectively. RESULTS: 29 eyes after XEN and 23 eyes after PF were included. Six months following OBR, IOP reduced from 24.2±4.7 to 13.5±4.6 after XEN and from 27.3±8.7 to 15.9±5.8mmHg after PF (both p<0.001). NoM did not change (0.7±1.3 to 0.4±0.8 after XEN and 1.2±1.3 to 1.0±1.5 after PF, p>0.05 for both). Complete SR were higher after XEN than after PF (58.6% vs. 30.4%, p=0.04). Complications were mild and managed mainly conservatively. Additional glaucoma surgery was needed in 17% and 30% of eyes after XEN and PF, respectively (p=0.26). CONCLUSION: Although OBR was effective as management of PBF following XEN and PF, SR were higher after XEN than after PF along with comparable safety profile. The change of the surgical approach from ab interno during XEN-Implantation to ab externo during OBR seems to enhance SR compared to PF, where both interventions are done ab externo.

7.
Diagnostics (Basel) ; 13(14)2023 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-37510061

RESUMO

Evaluation of bleb morphology is a vital part of successful filtration glaucoma surgery. The PRESERFLO-MicroShunt (PRESERFLO) and XEN-Gel-Stent (XEN) are drainage devices implanted using different surgical approaches (ab externo and ab interno, respectively), potentially resulting in distinct bleb morphology. Understanding these morphological differences is essential for postoperative care. In this study, we retrospectively examined functioning blebs following PRESERFLO and XEN implantation using high-resolution anterior segment OCT imaging. Qualitative assessment utilizing the Jenaer Bleb Grading System and quantitative assessment measuring 12 parameters representing bleb dimensions were conducted, and the results were compared between the two groups. A total of 80 eyes from 80 patients were included (41 after PRESERFLO, 39 after XEN). Functioning blebs following PRESERFLO exhibited a higher frequency of hyperreflective tenon changes compared to XEN (31.7% vs. 10.3%, respectively, p = 0.02) and a lower frequency of cavernous changes (17.1% vs. 35.9%, p = 0.05). Additionally, PRESERFLO blebs showed a higher frequency of visible episcleral lakes (92.7% vs. 30.8%, p < 0.001). Furthermore, PRESERFLO blebs demonstrated larger height (2.13 ± 0.5 vs. 1.85 ± 0.6 mm, p = 0.03), width (10.31 ± 2.3 vs. 9.1 ± 2.3 mm, p = 0.02), length (9.13 ± 1.8 vs. 8.24 ± 1.9 mm, p = 0.04), posterior location relative to the limbus (6.21 ± 1.2 vs. 5.21 ± 1.8 mm, p = 0.005), and a thicker bleb wall (1.60 ± 0.5 vs. 1.1 ± 0.4 mm, p = 0.004). Functioning blebs following PRESERFLO and XEN displayed morphological distinctions, likely attributed to variations in surgical techniques (ab externo vs. ab interno) and stent dimensions. These morphological differences should be taken into consideration when evaluating blebs, as they could impact assessments of bleb functionality and influence decisions regarding postoperative interventions.

9.
Klin Monbl Augenheilkd ; 240(7): 891-896, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36746398

RESUMO

PURPOSE: To evaluate the standard of care, in particular the use of topical or subconjunctival interferon-α2b, in treating ocular surface squamous neoplasia or melanocytic tumours in tertiary eye centres in Germany. METHODS: A survey containing 14 questions was sent to 43 tertiary eye centres in Germany. The questions addressed the surgical and medical management of ocular surface squamous neoplasia and melanocytic tumours (primary acquired melanosis and malignant melanoma), as well as the clinical experiences and difficulties in prescribing off-label interferon-α2b eye drops and subconjunctival injections. RESULTS: Twenty-four tertiary eye centres responded to the survey. Eighty-three percent of centres had used interferon-α2b in their clinical practice and 25% prescribed it as the first-line cytostatic agent following surgical excision of ocular surface squamous neoplasia, while 10% would do so for melanocytic tumours. Correspondingly, the majority of respondents selected mitomycin C as their first-line agent. Side effects were uncommon with topical interferon-α2b eye drops but were more frequently reported after subconjunctival interferon-α2b injections. In total, eight centres had experience with interferon-α2b injections. The most significant obstacles perceived by ophthalmologists when prescribing interferon-α2b were its high cost and the reimbursement thereof. CONCLUSION: Off-label mitomycin C was the preferred adjuvant therapy for epithelial and melanocytic tumours, with interferon-α2b being the standard second-line option. Interferon-α2b has predominantly been used to treat ocular surface squamous neoplasia and, to a lesser extent, melanocytic tumours at German tertiary eye centres. Following its market withdrawal, supply shortages of interferon-α2b are likely to have a profound impact on patient care and their quality of life.


Assuntos
Carcinoma de Células Escamosas , Neoplasias da Túnica Conjuntiva , Humanos , Mitomicina/uso terapêutico , Qualidade de Vida , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/cirurgia , Interferon-alfa/uso terapêutico , Interferon-alfa/efeitos adversos , Neoplasias da Túnica Conjuntiva/tratamento farmacológico , Inquéritos e Questionários , Soluções Oftálmicas , Proteínas Recombinantes/uso terapêutico
10.
Ophthalmologie ; 120(5): 529-537, 2023 May.
Artigo em Alemão | MEDLINE | ID: mdl-36445475

RESUMO

BACKGROUND: The implantation of a XEN gel stent is an innovative method for filtration surgery using an ab interno approach. The morphological evaluation of the resulting bleb is decisive for surgical success. Bleb revision is frequently needed after XEN implantation and might affect the bleb morphology. Aim of this study was to examine bleb morphology using anterior segment OCT (AS-OCT) and analyze the morphological differences of blebs after primary XEN implantation and after bleb revision. MATERIAL AND METHODS: Included were eyes that underwent XEN implantation (Pr-X) or bleb revision after XEN (Re­X group). An AS-OCT of blebs was performed and images were classified using a novel classification system (the Jenaer bleb grading system, JBGS). Frequency of different tomographic patterns (M) and their correlation with intraocular pressure (IOP) were analyzed. RESULTS AND DISCUSSION: A total of 69 eyes (40 in the Pr­X and 29 in the Re­X groups) were included. At the conjunctival level, the most common M in both groups was subconjunctival spaces (M-C2) followed by intraconjunctival cysts (C1) and no conjunctival changes (C0). No differences of frequencies between the two groups or of IOP between the three Ms were seen. At the tenon level, the most commonly seen Ms in the Pr­X group were hyporeflective and cavernous changes (M-T2, T3) followed by no changes (M0) and hyperflective changes (T1). In the Re­X group, the M­T1 and T2 were most commonly seen followed by T3 and T0. The M­T2 and T3 in the Pr­X group and the M­T1 and T2 in the Re­X group correlated with lower IOP. An episcleral lake (M-ES1) was seen significantly less frequently in the Pr­X group compared with Re­X group where it correlated with lower IOP CONCLUSION: The hyperreflective changes at the tenon level and the presence of an episcleral lake were seen more frequently following bleb revision compared with primary XEN implantation and correlated with lower IOP. The interpretation of bleb morphology using AS-OCT should only be done considering the surgical approach used.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Humanos , Tomografia de Coerência Óptica/métodos , Glaucoma de Ângulo Aberto/cirurgia , Túnica Conjuntiva/diagnóstico por imagem , Stents
11.
Int Ophthalmol ; 43(6): 1861-1865, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36436169

RESUMO

PURPOSE: Ocular surface squamous neoplasia (OSSN) has a high recurrence rate if only treated with surgical excision, especially in cases with positive excision margins. To reduce recurrence, we used brachytherapy after surgical excision for limbal and bulbar lesions in addition to chemotherapy/immunotherapy, cryotherapy, or external beam radiotherapy as adjunctive or primary therapies. METHODS: Nine eyes with isolated OSSN lesions were included in the study. Adjunctive brachytherapy with Ruthenium106-plaques was administered. The follow-up included regular biomicroscopic slit-lamp examination and photo-documentation. Additionally, a staging check for metastasis was performed in cases with squamous cell carcinoma (SCC). RESULTS: The average age of patients at the time of presentation was 66 ± 12 years. Follow-up time was 52.8 ± 44.6 months. The maximal tumour base varied between 3 and 28 mm. SCC was confirmed by histology in all cases. No recurrences were recorded during the follow-up, and organ salvage and eye function preservation were achieved. Radiotherapy-induced complications included secondary glaucoma (n = 1) and scleral melting (n = 1). Other complications, such as radiogenic retinopathy, were not observed. CONCLUSION: Brachytherapy with Ruthenium106-plaques offers an additional option for adjunct treatment of limbal and bulbar OSSN presenting with only a focal spread. Organ salvage can be achieved with a low complication rate and recurrence-free survival. This technique offers globe salvage in patients with tumours involving intraocular infiltration.


Assuntos
Braquiterapia , Carcinoma de Células Escamosas , Neoplasias da Túnica Conjuntiva , Neoplasias Oculares , Rutênio , Humanos , Pessoa de Meia-Idade , Idoso , Procedimentos Cirúrgicos Oftalmológicos/métodos , Estudos Retrospectivos , Neoplasias da Túnica Conjuntiva/diagnóstico , Carcinoma de Células Escamosas/radioterapia , Carcinoma de Células Escamosas/patologia , Neoplasias Oculares/patologia
12.
Can J Ophthalmol ; 58(6): 543-549, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35940212

RESUMO

OBJECTIVE: To evaluate the midterm results of tumour resection with or without adjunctive therapy for ocular surface squamous neoplasia of the fornix, including conjunctival reconstruction with buccal mucosa and amniotic membrane. METHODS: A retrospective case-series analysis including slit-lamp examination, photographic documentation, and biopsy results (repeated when clinical findings changed). Analysis centred on eye function, complications, additional procedures, and recurrence rate. Surgical technique included tumour resection and subsequent reconstruction of lost conjunctiva with buccal mucosa and amniotic membrane. RESULTS: We included 83 affected eyes from 76 patients (mean age, 63.10 ± 14.45 years; 34 females) seen over a mean follow-up period of 26.56 ± 21.17 months. We achieved bulbus oculi salvage in 82 eyes (98.79%) and typically preserved visual acuity (mean 0.2 ± 0.5 logMAR and 0.3 ± 0.5 logMAR at presentation and last follow-up, respectively). Moreover, only 23 patients (27.71%) required corrective surgery for clinically relevant complications. The main complications included symblepharon (9.64%; n = 8), cicatricial ectropion (9.64%; n = 8), pannus (9.64%; n = 8), and corneal decompensation (8.43%; n = 7). Local tumour recurrence was seen in 23 patients (27.71%). CONCLUSIONS: These midterm results confirm the efficacy of conjunctival reconstruction with amniotic membrane and buccal mucosa after resection of ocular surface squamous neoplasia from the fornix with palpebral and bulbar conjunctiva involvement. We not only achieved good tumour control and organ salvage with high levels of organ preservation but we also achieved good functional outcomes and acceptable recurrence rates. All clinically significant complications could be corrected in separate procedures.


Assuntos
Carcinoma de Células Escamosas , Neoplasias da Túnica Conjuntiva , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Mucosa Bucal , Âmnio/transplante , Estudos Retrospectivos , Túnica Conjuntiva/cirurgia , Túnica Conjuntiva/patologia , Neoplasias da Túnica Conjuntiva/diagnóstico , Neoplasias da Túnica Conjuntiva/cirurgia , Neoplasias da Túnica Conjuntiva/patologia , Carcinoma de Células Escamosas/cirurgia
13.
Acta Ophthalmol ; 101(2): e154-e166, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36017579

RESUMO

PURPOSE: To observe fundus autofluorescence (FAF) lifetimes and peak emission wavelength (PEW) of drusen with respect to the pathology of the overlying RPE in the follow-up of AMD-patients. METHODS: Forty eyes of 38 patients (age: 75.1 ± 7.1 years) with intermediate AMD were included. FAF lifetimes and PEW were recorded by fluorescence lifetime imaging ophthalmoscopy (FLIO). Twenty-six eyes had a follow-up investigation between months 12 and 36, and 10 at months 37-72. AMD progression was retrieved from color fundus photography (CFP) and OCT. Drusen were classified with respect to changes in the overlying RPE into groups no, questionable or faint, and apparent hyperpigmentation based on CFP. RESULTS: Among the 210 hyperautofluorescent drusen found at baseline, those with hyperpigmentation had longer lifetimes and shorter PEW than those without. Drusen without hyperpigmentation had shorter lifetimes and PEW than neighboring RPE (all p < 0.001) at baseline, but drusen lifetimes increased, and PEW shortened further over follow-up. Eyes, showing AMD progression, had significantly longer FAF lifetimes at baseline than non-progressing eyes: 282 ± 102 ps versus 245 ± 98 ps, p < 0.001 and 365 ± 44 ps vs. 336 ± 48 ps, p = 0.025 for short and long wavelength FLIO channel, respectively. CONCLUSIONS: Depending on hyperpigmentation properties, drusen show lifetimes and PEW different from that of adjacent RPE which change over the natural history of AMD. This difference and change, however, might reflect progressive dysmorphia of the RPE rather than representing fluorescence of drusen material itself. Nevertheless, the observed FAF changes could make FLIO a useful tool for the early detection of AMD progression risk.


Assuntos
Degeneração Macular , Drusas Retinianas , Humanos , Idoso , Idoso de 80 Anos ou mais , Angiofluoresceinografia/métodos , Retina/patologia , Degeneração Macular/diagnóstico , Degeneração Macular/patologia , Oftalmoscopia/métodos , Fundo de Olho , Tomografia de Coerência Óptica/métodos , Drusas Retinianas/diagnóstico
14.
J Glaucoma ; 32(2): 117-126, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35980859

RESUMO

PRCIS: A novel qualitative tomographical classification for bleb after implantation of XEN-Gel-Stent using ab interno approach is presented. Association of anatomic patterns to intraocular pressure (IOP) and success rates (SR) illustrates that anterior segment optical coherence tomography can be useful tool in clinical guidance. PURPOSE: To present a novel classification of bleb resulting from ab interno implantation of XEN-Gel-Stent and report association of tomographical patterns with IOP and SR. MATERIALS AND METHODS: A cross-sectional 1-armed study of patients receiving XEN-Gel-Stent. Tomographical changes in the bleb area were studied using swept-source optical coherence tomography in an early (d 29-90 postsurgery) and late (starting from d 91 postsurgery) phase. Frequency of patterns and their association with IOP and SR (defined as IOP<18 mmHg without medications) were studied. RESULTS: One hundred eleven examinations of 49 blebs (49 patients) were included. Three tomographical patterns at conjunctival, 4 at tenons capsule, and 2 at episcleral level were characterized. Most frequent conjunctival pattern was subconjunctival spaces (56.3% and 53.2% in the early and late phase, respectively) and associated with lower IOP (13.0±6.0 mmHg) and higher SR (89%) but only in the early phase compared with other conjunctival patterns ( P <0.05). At tenons capsule level, the hyporeflective pattern was most frequent (50% and 51.9% in early and late phase) followed by the cavernous pattern. Both patterns associated with lower IOP and higher SR compared with hyper-reflective or loss of tenon changes ( P <0.005). Most blebs showed no episcleral lake (87.5% and 89.9% in early and late phase). No difference of IOP and SR was noted compared with those showing an episcleral lake. CONCLUSION: A practical and clinically relevant novel classification system is proposed to tomographically describe and classify blebs after implantation of XEN-Gel-Stent. Certain patterns were associated with lower IOP and higher SR.


Assuntos
Pressão Intraocular , Stents , Humanos , Estudos Transversais , Tomografia de Coerência Óptica/métodos
15.
Invest Ophthalmol Vis Sci ; 63(13): 23, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36580310

RESUMO

Purpose: To measure fundus autofluorescence (FAF) lifetimes and peak emission wavelengths (PEW) of subretinal drusenoid deposits (SDD) in age-related macular degeneration (AMD) and their development over time. Methods: Fluorescence lifetime imaging ophthalmoscopy (FLIO) was performed in 30 eyes with optical coherence tomography (OCT)-confirmed early or intermediate AMD and SDD. Contrasts of mean lifetimes in short- (SSC) and long-wavelength channels (LSC), PEW, and relative fluorescence intensity were determined as differences of the respective measures at individual SDD and their environment. Measurements were made at baseline and at follow-up intervals 1 (13-36 months) and 2 (37-72 months), respectively. Results: Of 423 SDD found at baseline, 259, 47, and 117 were hypoautofluorescent, isoautofluorescent, and hyperautofluorescent, respectively. FAF lifetimes of SDD were significantly longer than those of their environment by 14.5 ps (SSC, 95% confidence interval [CI], 13.3-15.7 ps) and 3.9 ps (LSC, 3.1-4.7 ps). PEW was shorter by 1.53 nm (1.07-1.98 nm, all contrasts P < 0.001) with higher contrasts for hyperfluorescent SDD. Over follow-up, SDD tended to hyperautofluorescence (relative intensities increased by 3.4% [95% CI, 2.9%-4.1%; P < 0.001] in follow-up 2). Hyperautofluorescence was associated with disruption of the ellipsoid zone on OCT. Disease progression to late-stage AMD was associated with higher lifetime contrast in SSC (15.9ps [14.2-17.6 ps] vs. 11.7 ps [9.9-13.5 ps], P < 0.001) at baseline. Conclusions: SDD show longer FAF lifetimes and shorter PEW than their environments. A high lifetime contrast of SDD in SSC might predict disease progression to late-stage AMD.


Assuntos
Degeneração Macular , Drusas Retinianas , Humanos , Angiofluoresceinografia/métodos , Degeneração Macular/diagnóstico , Degeneração Macular/complicações , Retina , Oftalmoscopia/métodos , Tomografia de Coerência Óptica/métodos , Progressão da Doença , Drusas Retinianas/diagnóstico
16.
Invest Ophthalmol Vis Sci ; 63(13): 5, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36469025

RESUMO

Purpose: The purpose of this study was to investigate histologic autofluorescence lifetimes and spectra of retinal pigment epithelium (RPE) on the transition from normal aging to RPE activation and migration in age-related macular degeneration (AMD). Methods: Autofluorescence lifetimes and spectra of 9 donor eyes were analyzed in cryosections by means of 2-photon excited fluorescence at 960 nm. Spectra were detected at 483 to 665 nm. Lifetimes were measured using time-correlated single photon counting in 2 spectral channels: 500 to 550 nm (short-wavelength spectral channel [SSC]) and 550 to 700 nm (long-wavelength spectral channel [LSC]). Fluorescence decays over time were approximated by a series of three exponential functions. The amplitude-weighted mean fluorescence lifetime was determined. Markers for retinoid activity (RPE65) and immune function (CD68) were immunolocalized in selected neighboring sections. Results: We identified 9 RPE morphology phenotypes resulting in 399 regions of interest (ROIs) for spectral and 497 ROIs for lifetime measurements. RPE dysmorphia results in a shorter wavelength peak of spectral emission: normal aging versus RPE migrated into the retina (intraELM) = 601.7 (9.5) nm versus 581.6 (7.3) nm, P < 0.001, whereas autofluorescence lifetimes increase: normal aging versus intraELM: SSC 180 (44) picosecond (ps) versus 320 (86) ps, P < 0.001; and LSC 250 (55) ps versus 441 (76) ps, P < 0.001. Ectopic RPE within the neurosensory retina is strongly CD68 positive and RPE65 negative. Conclusions: In the process of RPE degeneration, comprising different steps of dysmorphia and migration, lengthening of autofluorescence lifetimes and a hypsochromic shift of emission spectra can be observed. These autofluorescence changes might provide early biomarkers for AMD progression and contribute to our understanding of RPE-driven pathology.


Assuntos
Degeneração Macular , Epitélio Pigmentado da Retina , Humanos , Epitélio Pigmentado da Retina/patologia , Oftalmoscopia/métodos , Degeneração Macular/diagnóstico , Degeneração Macular/patologia , Retina/patologia , Tomografia de Coerência Óptica/métodos , Angiofluoresceinografia/métodos
17.
Biomed Opt Express ; 13(10): 5483-5494, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36425633

RESUMO

Fluorescence lifetime imaging ophthalmoscopy (FLIO) provides information on fluorescence lifetimes in two spectral channels as well as the peak emission wavelength (PEW) of the fluorescence. Here, we combine these measures in an integral three-dimensional lifetime-PEW metric vector and determine a normal range for this vector from measurements in young healthy subjects. While for these control subjects 97 (±8) % (median (interquartile range)) of all para-macular pixels were covered by this normal vector range, it was 67 (±55) % for the elderly healthy, 38 (±43) % for age-related macular degeneration (AMD)-suspect subjects, and only 6 (±4) % for AMD patients. The vectors were significantly different for retinal pigment epithelium (RPE) lesions in AMD patients from that of non-affected tissue (p < 0.001). Lifetime- PEW plots allowed to identify possibly pathologic fundus areas by fluorescence parameters outside a 95% quantile per subject. In a patient follow-up, changes in fluorescence parameters could be traced in the lifetime-PEW metric, showing their change over disease progression.

18.
Exp Clin Endocrinol Diabetes ; 130(10): 652-659, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35940177

RESUMO

AIMS: No information exists on the frequency of visual impairment in people with diabetes mellitus (DM) in Germany. In this study, the prevalence of vision impairment in those individuals was investigated. METHODS: We retrospectively analyzed a cohort of 295 people (14221 consultations) at a university outpatient clinic with any type of DM and an available ETDRS-Score and visual acuity. The primary outcome was the prevalence of visual impairment, the secondary outcome was the correlation of the ETDRS-Score and limitations of visual acuity and the prevalence of higher ETDRS-Score with a visual impairment defined as a decimal-visus

Assuntos
Diabetes Mellitus Tipo 2 , Retinopatia Diabética , Humanos , Prevalência , Estudos Retrospectivos , Retinopatia Diabética/epidemiologia , Retinopatia Diabética/complicações , Acuidade Visual , Transtornos da Visão/epidemiologia , Transtornos da Visão/etiologia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia
19.
Graefes Arch Clin Exp Ophthalmol ; 260(11): 3587-3595, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35666297

RESUMO

PURPOSE: To investigate the haemoglobin concentration and oxygenation in the optic disc in glaucoma patients vs. controls. METHODS: Thirty-one eyes of primary open angle glaucoma patients (mean age: 64.9 ± 2.1 years) and 31 eyes of 31 healthy controls (65.5 ± 2.0 years) were included. Perimetry, optical coherence tomography (OCT), and OCT angiography were performed. Multispectral imaging was used to record the optic disc reflectance at wavelengths 522 nm, 548 nm, 555 nm, 586 nm, and 610 nm, and haemoglobin concentration and oxygenation (SO2) were calculated from these measures. This was done in the rest and under stimulation of neuronal activity by flicker light. RESULTS: The haemoglobin concentration was significantly lower (p < 0.001) in the rim (40.0 ± 6.3) and the excavation (35.7 ± 8.0) of the glaucoma patients' discs than in controls (45.7 ± 7.5). SO2 was not different in general, but lower in a subgroup of 18 glaucoma patients with ischaemic disc rims than in non-ischaemic ones (median 26.8%, interquartile range (IQR): 29.5% vs. 51.9%, IQR 32.0%, p = 0.02) as well as in controls (41.0%, IQR 30.6%, p = 0.01). Flicker light stimulation significantly increased the haemoglobin concentration in the controls (+ 1.3 ± 3.6, p = 0.048) as well as in the rim of glaucoma discs (+ 2.6 ± 5.0, p = 0.006) and SO2 in the controls only (+ 15.4 ± 23.6%, p = 0.001). The haemoglobin concentration was significantly correlated with the perimetric mean defect, retinal nerve fibre layer (RNFL) thickness and para-papillary perfusion density. CONCLUSIONS: The optic disc haemoglobin concentration and oxygenation are quantifiable from multispectral imaging and reduced in glaucoma. The correlation of haemoglobin concentration with perfusion density, RNFL thickness and visual field loss indicates its implication in glaucoma pathology.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Disco Óptico , Humanos , Pessoa de Meia-Idade , Idoso , Disco Óptico/patologia , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/patologia , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Glaucoma/patologia , Testes de Campo Visual/métodos , Tomografia de Coerência Óptica/métodos , Hemoglobinas , Perfusão , Pressão Intraocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA